7397 Seneca Street, East Aurora NY 14052 Ph: (716) 674-0883 Fx: (716) 674-0884 GCallahan@demcoinc.com
Power Services Home
D&D of Trojan Power Plant

  • Provided specialized expertise in the decommissioning & demolition of the uncontaminated systems, components and structures at the former Trojan Power Plant.
  • Performed full asbestos abatement work on all structures demolished, including approximately 58,000 pounds of ACM and 86,500 pounds of Galbestos siding.
  • Implemented ACM controls and removal methodology that were reviewed and approved by a third party consultant.
  • Removal work consisted of interior enclosures, exterior intact and component dismantling for access to ACM parts within the turbine generator.
  • Demolished structures included the Turbine Building, Control Building, Auxiliary Building, Fuel Building, Tank Area, Main Steam Support Structure, Circulating Water Pump Area and Administrative Building.
  • Recycled an estimated 6,000 tons of structure steel and 10,000 tons of concrete for crushing and reuse onsite.
  • Work included the implementation and management of work control packages, and complete safety management of DEMCO and subcontractor personnel.